UNIBLITZ electronic drive equipment converts line voltage to that necessary to operate all UNIBLITZ shutters. If the user is to design custom OEM drive circuitry, it is highly recommended to contact one of our technical representatives for design assistance.

Download Shutter Products - Comparison Specifications PDFPDF Icon
SERIES COIL RESISTANCE PULSE VOLTAGE TO OPEN HOLD VOLTAGE1 (NOMINAL)
BDS25 12 OHMS (OPEN)
12 OHMS (CLOSE)
+65VDC (OPEN)
+65 VDC (CLOSE)
N/A (BOTH COILS)
CS25 12 OHMS +65 VDC +5 VDC
CS35 12 OHMS +70 VDC +7 VDC/+5VDC2
CS45 12 OHMS +70 VDC +7 VDC/+5VDC2
CS65 12 OHMS +70 VDC +7 VDC/+5VDC2
CS90 12 OHMS (each coil) +70VDC Primary
+7VDC Aux3
+7VDC/+5VDC Primary
LS2 48 OHMS +65 VDC +10 VDC
LS3 48 OHMS +65 VDC +10 VDC
LS6 48 OHMS +65 VDC +10 VDC
QCS45 12 OHMS +70 VDC +7 VDC/+5VDC2
UHS1 12 OHMS (each coil) +65 VDC +5 VDC
VS14 12 OHMS +65 VDC +5 VDC
VS25 12 OHMS +65 VDC +5 VDC
VS35 12 OHMS +70 VDC +7VDC/+5VDC2
XRS14 12 OHMS +65 VDC +5 VDC
XRS25
(each coil)
12 OHMS +65 VDC +5 VDC
XRS6 12 OHMS +65 VDC +5 VDC

1 Voltage level required across actuator coil when being held in the open position

2 Dual hold voltage level driver system included in UNIBLITZ VMM/VCM shutter controller.

3 Drive system is on-board for CS90 auxiliary actuator. When using a UNIBLITZ drive system (i.e. VMM or VCM series) 7.0VDC level is supplied. When operating this device without UNIBLITZ drive equipment, (i.e. using a driver of your own design, etc.) please request and review the CS90 Shutter Electrical Configuration Layout.